Guangzhou Kingrise Enterprises Co., Ltd.
Stationary Test Equipment
KE8104
Single Phase Meter Test System
Accuracy: 0.05
Number of meter position: 3-48
Double current channels with ICT isolation
Used for 2 element single phase mechanical and electric meter,

Highlight

² Integrated / Separated aluminum alloy structure, light andreliable, flexible choices

² The number of meter positions can be chosenfrom 3 - 48

² Perfect alarming protective function, auto protection ofthe short circuit of voltage, the open circuit of current, and overload.

² Full automatic, semi automatic and manual operationavailable

² Supporting bar code input, which increase the efficiencyof input

² Simultaneous test of the energy meters with samespecification, different constants and different classes.

² Auto mark locking increases the efficiency oftest

² Forward and reverse active energy / forward and reversereactive energy error test

² Creeping and starting test

² Standard deviation, 24 hour variation test

² Influencing quantity test of voltage, frequency, harmonic

² Calibration and verification of energy constant

² Powerful computer management system, easy anduser-friendly

² Perfect database management makes thestorage, searching,and viewing of the data possible, and the data can be converted and exported inother forms

² The test of open circuit for Neutral voltage (optional)

² Adopt multi-serial port system, realizing the parallelcommunication of computer and the tested meters (optional)


WiringDiagram


 

Main Specification

 

KE8104-6

KE8104-12

KE8104-24

KE8104-48

Number of meter position

6

12

24

48

Accuracy

±0.05%

Voltage output

Output range (P-N)

24V – 300V

Output power of voltage

150VA

250VA

500VA

1000VA

Resolution

Better than ± 0.01%

Stability

Better than ± 0.02% / 150s

Load regulation rate

Better than ± 0.01%

Distortion factor

Better than ± 0.3% (linear resistance load)

Harmonics output

2nd -21st free programmable

Current output

Output range

1mA – 120A (or customizedMax. 230A)

1mA – 120A

Output power of current

500VA

750VA

1500VA

3000VA

Resolution

Better than ± 0.01%

Stability

Better than ± 0.02% / 150s

Load regulation rate

Better than ± 0.01%

Distortion factor

Better than ± 0.3% (linear resistance load)

Harmonics output

2nd -21st free programmable

Phase output

Output range

0 -- 360°

Resolution

± 0.01°

Frequency

Output range

45Hz – 65Hz

Resolution

± 0.01Hz

Operation condition

Power supply

220V±10%50/60Hz±2Hz

Temperature

-10°C -- +40°C

Humidity

35% -- 85%RH