Guangzhou Kingrise Enterprises Co., Ltd.
Stationary Test Equipment
KE8103
Single Phase Meter Test System
Accuracy: 0.05
Number of meter position: 3-48
Two current sources, used for testing 1P2W / 1P3W or 3P3W mechanical and electric meter,

.Highlight

²  Integrated/Separated aluminum alloy structure, light and reliable, flexible choices

²  The number of meter positions can be chosen from 6 - 48

²  Perfect alarming protective function, auto protection of the short circuit ofvoltage,the open circuit of current, and overload.

²  Full automatic, semi automatic and manual operation available

²  Supporting bar code input, which increase the efficiency of input

²  Simultaneous test of the energy meters with same specification, different constants anddifferent classes.

²  Auto marklocking increases the efficiency of test

²  Forward and reverse active energy / forward and reverse reactive energy error test

²  Creeping and starting test

²  Standard deviation, 24 hour variation test

²  Influencing quantity test of voltage, frequency, harmonic

²  Calibration and verification of energy constant

²  Powerful computer management system, easy and user-friendly

²  Perfect database management makes the storage, searching, and viewing of the datapossible, and the data can be converted and exported in other forms

²  The test of open circuit for Neutral voltage (optional)

²  Adopt multi-serial port system, realizing the parallel communication of computerandthe tested meters (optional)

 

Wiring Diagram

 

Main Specification

 

 

KE8103-6

KE8103-12

KE8103-24

KE8103-48

Number of meter position

6

12

24

48

Accuracy

±0.05%

Voltage output

Output range (P-N)

24V – 300V

Output power of voltage

2x 150VA

2x 250VA

2x 500VA

2x 1000VA

Resolution

Better than ± 0.01%

Stability

Better than ± 0.02% / 150s

Load regulation rate

Better than ± 0.01%

Distortion factor

Better than ± 0.3% (linear resistance load)

Harmonics output

2nd -21st free programmable

Current output

Output range

1mA – 120A (or customizedMax. 230A)

1mA – 120A

Output power of current

2x 350VA

2x 500VA

2x 1000VA

2x 2000VA

Resolution

Better than ± 0.01%

Stability

Better than ± 0.02% / 150s

Load regulation rate

Better than ± 0.01%

Distortion factor

Better than ± 0.3% (linear resistance load)

Harmonics output

2nd -21st free programmable

Phase output

Output range

0 -- 360°

Resolution

± 0.01°

Frequency

Output range

45Hz – 65Hz

Resolution

± 0.01Hz

Operation condition

Power supply

220V±10%50/60Hz±2Hz

Temperature

-10°C -- +40°C

Humidity

35% -- 85%RH