Guangzhou Kingrise Enterprises Co., Ltd.
Stationary Test Equipment
KE8102
Single Phase Meter Test System
Accuracy: 0.05
Number of meter position: 3-64
Multiple switchable channels for current output,
Used for testing 2 or 3 elements single phase mechanical and electric meter,

Highlight

 

·        Integrated / Separated aluminum alloy structure, lightand reliable, flexible choices

·        The numberof meter positions can be chosen from 3 - 64

·        Perfect alarming protective function, auto protection ofthe short circuit of voltage, the opencircuit of current, and overload.

·        Full automatic, semi automatic and manual operationavailable

·        Supporting bar code input, which increase the efficiencyof input

·        Simultaneous test of the energy meters with same specification, different constant and different class.

·        Auto mark locking increases the efficiency of test

·        Forward and reverse active energy / forward and reversereactive energy error test

·        Creeping and starting test

·        Standard deviation, 24 hour variation test

·        Influencing quantity test of voltage, frequency, harmonic

·        Calibration and verification of energy constant

·        Powerful computer management system, easy anduser-friendly

·        Perfect database management makes the storage, searching,and viewing of the data possible, and the data can be converted and exported inother forms

·        The testof open circuit for Neutral voltage (optional)

·        Adopt multi-serial port system, realizing the parallelcommunication of computer andthe tested meters (optional)

 

Wiring Diagram


 

MainSpecification

 

 

KE8102-6

KE8102-12

KE8102-24

KE8102-48

KE8102-64

Number of meter position

6

12

24

48

64

Accuracy

±0.05%

Voltage output

Output range (P-N)

24V – 300V

Output power of voltage

150VA

250VA

500VA

1000VA

1500VA

Resolution

Better than ± 0.01%

Stability

Better than ± 0.02% / 150s

Load regulation rate

Better than ± 0.01%

Distortion factor

Better than ± 0.3% (linear resistance load)

Harmonics output

2nd -21st free programmable

Current output

Output range

1mA – 120A (or customizedMax. 230A)

1mA – 120A

Output power of current

350VA

500VA

1000VA

2000VA

3000VA

Resolution

Better than ± 0.01%

Stability

Better than ± 0.02% / 150s

Load regulation rate

Better than ± 0.01%

Distortion factor

Better than ± 0.3% (linear resistance load)

Harmonics output

2nd -21st free programmable

Phase output

Output range

0 -- 360°

Resolution

± 0.01°

Frequency

Output range

45Hz – 65Hz

Resolution

± 0.01Hz

Operation condition

Power supply

220V±10%50/60Hz±2Hz

Temperature

-10°C -- +40°C

Humidity

35% -- 85%RH