Guangzhou Kingrise Enterprises Co., Ltd.
Stationary Test Equipment
KE8101
Single Phase Meter Test System
Accuracy: 0.05
Number of meter position: 3-96
Used for testing various single phase electric and mechanical meter,

Highlight

 

²  Integrated / Separated aluminum alloystructure, light and reliable,flexible choices

²  The number of meter positions can bechosen from 3 - 96

²  Perfect alarming protective function, autoprotection of the short circuitof voltage,the open circuit of current, andoverload.

²  Full automatic, semi automatic and manualoperation available

²  Supporting bar code input, which increasethe efficiency of input

²  Simultaneous test of the energy meterswith same specification, different constants and different classes.

²  The test of open circuit for Neutralvoltage (optional)

²  Auto mark locking increases the efficiencyof test

²  Forward and reverse active energy /forward and reverse reactive energy error test

²  Creeping and starting test

²  Standard deviation, 24 hour variation test

²  Influencing quantity test of voltage,frequency, harmonic

²  Calibration and verification of energyconstant

²  Powerful computer management system, easyand user-friendly

²  Perfect database management makes thestorage, searching, and viewing ofthe data possible, and the data can beconverted and exported in other forms

²  Adopt multi-serial port system, realizingthe parallel communication of computer and the tested meters (optional)

 

Wiring Diagram

 

 

Main Specification

 

 

KE8101-12

KE8101-24

KE8101-48

KE8101-64

KE8101-96

Number of meter position

12

24

48

64

96

Accuracy

±0.05%

Voltage output

Output range (P-N)

24V – 300V

Output power of voltage

250VA

500VA

1000VA

1500VA

2000VA

Resolution

Better than ± 0.01%

Stability

Better than ± 0.02% / 150s

Load regulation rate

Better than ± 0.01%

Distortion factor

Better than ± 0.3% (linear resistance load)

Harmonics output

2nd -21st free programmable

Current output

Output range

1mA – 120A (or customizedMax. 230A)

1mA – 120A

Output power of current

350VA

750VA

1500VA

2000VA

3000VA

Resolution

Better than ± 0.01%

Stability

Better than ± 0.02% / 150s

Load regulation rate

Better than ± 0.01%

Distortion factor

Better than ± 0.3% (linear resistance load)

Harmonics output

2nd -21st free programmable

Phase output

Output range

0 -- 360°

Resolution

± 0.01°

Frequency

Output range

45Hz – 65Hz

Resolution

± 0.01Hz

Operation condition

Power supply

220V±10%50/60Hz±2Hz

Temperature

-10°C -- +40°C

Humidity

35% -- 85%RH