Guangzhou Kingrise Enterprises Co., Ltd.
Stationary Test Equipment
KE8302-1000
1000A Three Phase Meter Test System
Accuracy: 0.05
Number of meter position: 1-6
Used for testing and calibration of single / three phase clamp CT meter, including on-site installed meter and portable standard meter.

Highlight

  • Integrated aluminum alloy structure, light and reliable, flexible choices
  • Meter positions can be chosen from 1-6
  • Auto protection of short circuit of voltage, open circuit of current, and overload.
  • Full automatic, semi-automatic and manual operation available
  • Supporting bar code input, which increase the efficiency of input
  • Simultaneous test of the meters with same specification, different constants and different classes.
  • Adopt multi-serial port system, realizing the parallel communication of computer and the tested meters (optional)
  • Forward and reverse active energy/ Forward and reverse reactive energy error test
  • Creeping and starting test
  • Standard deviation, 24 hour variation test
  • Influencing quantity test of voltage, frequency, harmonic
  • Calibration and verification of constant
  • Register indicating value, register combination error test
  • Powerful computer management system, easy and user-friendly
  • Perfect database management makes the storage, searching, and viewing of the data possible, and the data can be converted and exported in other forms


Main specifications

KE8302-1000-3

KE8302-1000-6

Number of meter position

3

6

Accuracy

± 0.05%

Voltage output

Output range (P-N)

3×(24V - 300V)

Output power of voltage

3×100VA

3×200VA

Resolution

Better than ± 0.01%

Stability

Better than ± 0.02% / 150s

Load regulation rate

Better than ± 0.01%

Distortion factor

Better than ± 0.3% (linear resistance load)

Harmonics output

2nd -21st free programmable

Current output

Output range

3×(0.5A - 1000A)

Output power of current

3×400VA

3×800VA

Resolution

Better than ± 0.01%

Stability

Better than ± 0.02% / 150s

Load regulation rate

Better than ± 0.01%

Distortion factor

Better than  ± 0.3% (linear resistance load)

Harmonics output

2nd -21st free programmable

Phase output

Output range

0 -- 360°

Resolution

± 0.01°

Frequency output

Output range

45Hz - 65Hz

Resolution

± 0.01Hz

Operation conditions

Power supply

3×220/380V±10% ,50/60Hz±2Hz

Temperature

-10°C -- +40°C

Humidity

35% -- 85%RH