KE7308 |
Portable Three Phase Standard Meter |
Accuracy : 0.05 / 0.1, Test method : terminal input or clamp CT , Protection degree : IP67, test the error of three phase energy meters and field electrical parameters of power grid |
Highlight:
· Wide current range (direct connection): 0.2A to 20A, the highest accuracy of each test point is 0.05%
· Calibrate the error of all electricity energy meters, checking the constant of the energy meter
· Simultaneous checking of the primary meter and the secondary meter in the same loop, or simultaneously checking of the active power meter and reactive power meter in the same loop
· 7” color LCD display, All the parameters of each operation function can be displayed within one page
· Two operation modes: touch screen and keyboard. Easy and reliable operation..
· Measure voltage, current,frequency, power, power factor and phase angle
· Simultaneous measure and display waveforms of three phase voltage and current
· Measure ratio of CT.
· Allocate clamp of 20A, 100A, 200A, 500A,1000A to directly measure the comprehensive error
· Measure the 2nd - 51st harmonics of current and voltage
· Display vector diagram, judge the wiring right or wrong automatically
· Industrial grade engineering plastic suit case, which has a safety protection level of up to IP67.
· Read the information of energy meter with barcode scanner (optional)
· Battery, test lead power or external power for choices
· Communicate with PC, download calibration data through USB flash disk, RS-232 port
· Firmware can be upgraded through removed disk by users themselves
· Save and browse the testing data
Main Specifications:
| KE7308-0.05 | KE7308-0.1 | |
Voltage measurement | |||
Voltage range | 0V – 450V | ||
Accuracy | ±0.05% | ±0.1% | |
Harmonics | 2nd- 51st | ||
Current measurement | |||
Current range | Terminal input | 0.05A – 20A | |
Clamp input | 5A, 20A, 100A, 200A, 500A, 1000A, 1500A | ||
Accuracy | Terminal input | ±0.05% | ±0.1% |
Clamp input | ±0.2% (5A to 200A)、±0.5% (others) | ||
Harmonics | 2nd- 51st | ||
Power measurement | |||
Active power | Terminal input | ±0.05% | ±0.1% |
Clamp input | ±0.2% (5A to 200A)、±0.5% (others) | ||
Reactive power | Terminal input | ±0.05% | ±0.1% |
Clamp input | ±0.2% (5A to 200A)、±0.5% (others) | ||
Energy measurement | |||
Active energy | Terminal input | ±0.05% | ±0.1% |
Clamp input | ±0.2% (5A to 200A)、±0.5% (others) | ||
Reactive power | Terminal input | ±0.05% | ±0.1% |
Clamp input | ±0.2% (5A to 200A)、±0.5% (others) | ||
Phase measurement | |||
Phase range | 0 -- 360° | ||
Accuracy | ±0.05° | ±0.1° | |
Frequency measurement | |||
Frequency range | 45Hz – 65Hz | ||
Accuracy | ±0.05Hz | ||
Pulse output | |||
Constant | 36000 imp / kWh (or customize) | ||
Pulse input | |||
Input channel | 2 | ||
Input frequency | Max. 100Hz | ||
Others | |||
Power supply | Build-in rechargeable battery, external power supply, powered from the tested terminal | ||
Dimensions | 323mm×275mm×135mm | ||
Weight | 3.5kg |