Guangzhou Kingrise Enterprises Co., Ltd.
Stationary Test Equipment
KE8300A
Three Phase Meter Test System
Accuracy: 0.01
Number of meter position: 3-6
Used for the test of standard meter and mounted meter with a accuracy class below 0.05,

Highlight:


·        High accuracy: 0.01%

·        Integrated / separated aluminum alloy structure, light and reliable, flexible choices

·        Meter positions can be chosen from 3 - 6

·        Auto protection of short circuit of voltage, open circuit of current, and overload.

·        Full automatic, semi automatic and manual operation available

·        Supporting bar code input, which increase the efficiency of input

·        Simultaneous test of the meters with same specification, different constants and different classes.

·        Forward and reverse active energy / forward and reverse reactive energy error test

·        Creeping and starting test

·        Standard deviation, 24 hour variation test

·        Timing error test

·        Influencing quantity test of voltage, frequency, harmonic

·        Calibration and verification of constant

·        Register indicating value, register combination error test

·        Powerful computer management system, easy and user-friendly

·        Perfect database management makes the storage, searching, and viewing of the data possible, and the data can be converted and exported in other forms

 

Main specifications:


 

KE8300A-3

KE8300A-6

Number of meter position

3

6

Accuracy

±0.01%

Voltage output

Output range (P-N)

3×(24V - 300V)

Output power of voltage

3×200VA

3×200VA

Resolution

Better than ± 0.001%

Stability

Better than ± 0.002% / 150s

Load regulation rate

Better than ± 0.01%

Distortion factor

Better than ± 0.05% (linear resistance load)

Harmonics output

2nd -21st free programmable

Current output

Output range

1mA - 120A

Output power of current

3×150VA

3×300VA

Resolution

Better than ± 0.001%

Stability

Better than ± 0.002% / 150s

Load regulation rate

Better than ± 0.01%

Distortion factor

Better than  ± 0.05% (linear resistance load)

Harmonics output

2nd -21st free programmable

Phase output

Output range

0 -- 360°

Resolution

± 0.01°

Frequency

Output range

45Hz – 65Hz

Resolution

± 0.001Hz

Operation condition

Power supply

220V±10%50/60Hz±2Hz

Temperature

-10°C -- +40°C

Humidity