Guangzhou Kingrise Enterprises Co., Ltd.
Portable Reference Standard Meter
KE7303
Portable Three Phase Standard Meter
Accuracy : 0.05 / 0.1, Test method : terminal input or clamp CT input, test the error of three phase energy meters and feild electrical parameters of power grid

Highlight

²           Calibrate the error of all electricity energy meters, checking the constant of the energy meter

²        Simultaneous checking of the primary meter and the secondary meter in the same loop, or simultaneously checking of the active power meter and reactive power meter inthe same loop

²        Measure voltage, current, frequency, power, power factor and phase angle

²        Simultaneous measure and display waveforms of three phase voltage and current

²        Detectthe error change of the clamp automatically; ensure the accuracy stability ofthe clamp and the instrument in the long run.

²        Measureratio of CT, VA burden of the metering loop from VT and CT secondary terminals.

²        Allocate clamp of 20A, 100A, 500A, 1000A to directly measure the comprehensive error

²        Measurethe 2nd – 51st harmonics of current and voltage

²        Display vector diagram, judge the wiring right or wrong automatically

²        Read the information of energy meter with barcode scanner (optional)

²        Battery, test lead power or external power for choices

²        Communicate with PC, download calibration data through USB flash disk, RS-232 or bluetooth 

²        Firmware can be upgraded through removed disk by users themselves

²        Save and browse the testing data, data storage quantity is 1000 group 

Main specifications

 

KE7303-0.05

KE7303-0.1

Voltage measurement

Voltage range

0V – 480V

Accuracy

±0.05%

±0.1%

Harmonics

2nd- 51st

Current measurement

Current range

Terminal input

0.1A – 10A

Clamp input

5A20A100A500A1000A2000A3000A

Accuracy

Terminal input

±0.05%

±0.1%

Clamp input

±0.2%5A)、±0.5% (others)

Harmonics

2nd- 51st

Power measurement

Active power

Terminal input

±0.05%

±0.1%

Clamp input

±0.2%5A)、±0.5% (others)

Reactive power

Terminal input

±0.05%

±0.1%

Clamp input

±0.2%5A)、±0.5% (others)

Energy measurement

Active energy

Terminal input

±0.05%

±0.1%

Clamp input

±0.2%5A)、±0.5% (others)

Reactive power

Terminal input

±0.05%

±0.1%

Clamp input

±0.2%5A)、±0.5% (others)

Phase measurement

Phase range

0 -- 360°

Accuracy

±0.05°

±0.1°

Frequency measurement

Frequency range

45Hz – 65Hz

Accuracy

±0.05Hz

Pulse output

High frequency outputCH

3.6×107imp / kWh

Low frequency outputCL

3.6×104imp / kWh

Pulse input

Input channel

2

Input frequency

Max. 100Hz

Others

Power supply

Build-in rechargeable battery, external power supply, powered from the tested terminal

Dimensions

154mm×249mm×58mm

Weight

1.8kg