KE8302 |
Three Phase Meter Test System |
Accuracy: 0.05 Number of meter position: 3-48 Used for the test of three phase and single phase I-P close link or I-P open link meter. |
² Integrated / separated aluminum alloy structure, light and reliable, flexible choices
² Meter positions can be chosen from 3 - 48
² Adopt ICT to test I-P close link meters
² Auto protections of short circuit of voltage, open circuit of current, and overload
² Test of neutral current (optional)
² Automark locking increases the efficiency of test
² Full automatic, semi automatic and manual operation available
² Supporting bar code input, which increase the efficiency of input
² Simultaneous test of the meters with same specification, different constants and different classes.
² Adopt multi-serial port system, realizing the parallel communication of computer and the tested meters( optional)
² Test of tilt impact (optional)
² Forward and reverse active energy / forward and reverse reactive energy error test
² Creeping and starting test
² Standard deviation, 24 hour variation test
² Timing error test
² Influencing quantity test of voltage, frequency, harmonic
² Calibration and verification of constant
² Register indicating value, register combination error test
² Powerful computer management system, easy and user-friendly
² Perfect database management makes the storage, searching, and viewing of the data possible, and the data can be converted and exported in other forms
| KE8302-6 | KE8302-12 | KE8302-24 |
Number of meter position | 6 | 12 | 24 |
Accuracy | ± 0.05% | ||
Voltage output | |||
Output range (P-N) | 3×(24V – 300V) | ||
Output power of voltage | 3×100VA | 3×250VA | 3×500VA |
Resolution | Better than ± 0.01% | ||
Stability | Better than ± 0.02% / 150s | ||
Load regulation rate | Better than ± 0.01% | ||
Distortion factor | Better than ± 0.3% (linear resistance load) | ||
Harmonics output | 2nd -21st free programmable | ||
Current output | |||
Output range | 3×(1mA – 120A) | ||
Output power of current | 3×500VA | 3×1000VA | 3×2000VA |
Resolution | Better than ± 0.01% | ||
Stability | Better than ± 0.02% / 150s | ||
Load regulation rate | Better than ± 0.01% | ||
Distortion factor | Better than ± 0.3% (linear resistance load) | ||
Harmonics output | 2nd -21st free programmable | ||
Phase output | |||
Output range | 0 -- 360° | ||
Resolution | ± 0.01° | ||
Frequency output | |||
Output range | 45Hz – 65Hz | ||
Resolution | ± 0.01Hz | ||
Operation conditions | |||
Power supply | 3×220/380V±10% ,50/60Hz±2Hz | ||
Temperature | -10°C -- +40°C | ||
Humidity | 35% -- 85%RH |