Guangzhou Kingrise Enterprises Co., Ltd.
Meter Test System
KE8301
Three phase meter test system
Accuracy: 0.05
Number of meter position: 3-48
Used for the test of three phase and single phase I-P open link meter

Highlight

²  Integrated / separated aluminum alloy structure, light and reliable, flexible choices

²  Meter positions can be chosen from 3 - 48

²  Auto protection of short circuit of voltage, open circuit of current, and overload.

²  Test of neutral current (optional)

²  Auto mark locking increases the efficiency of test

²  Full automatic, semi automatic and manual operation available

²  Supporting barcode input, which increase the efficiency of input

²  Simultaneous test of the meters with same specification, different constants and different classes.

²  Adopt multi-serial port system, realizing the parallel communication of computer and the tested meters( optional)

²  Test of tilt impact (optional)

²  Forward and reverse active energy / forward and reverse reactive energy error test

²  Creeping and starting test

²  Standard deviation, 24 hour variation test

²  Timing error test

²  Influencing quantity test of voltage, frequency, harmonic

²  Calibration and verification of constant

² Register indicating value, register combination error test

²  Powerful computer management system, easy and user-friendly

²  Perfect database management makes the storage, searching, and viewing of the data possible, and the data can be converted and exported in other forms

Main specifications

 

KE8301-6

KE8301-12

KE8301-24

KE8301-48

Number of meter position

6

12

24

48

Accuracy

± 0.05%

Voltage output

Output range (P-N)

3×(24V – 300V)

Output power of voltage

3×100VA

3×250VA

3×500VA

3×1000VA

Resolution

Better than ± 0.01%

Stability

Better than ± 0.02% / 150s

Load regulation rate

Better than ± 0.01%

Distortion factor

Better than ± 0.3% linear resistance load

Harmonics output

2nd -21st free programmable

Current output

Output range

1mA – 120A (or customizedMax. 230A)

3×(1mA – 120A)

Output power of current

3×150VA

3×350VA

3×750VA

3×1500VA

Resolution

Better than ± 0.01%

Stability

Better than ± 0.02% / 150s

Load regulation rate

Better than ± 0.01%

Distortion factor

Better than  ± 0.3% linear resistance load

Harmonics output

2nd -21st free programmable

Phase output

Output range

0 -- 360°

Resolution

± 0.01°

Frequency output

Output range

45Hz – 65Hz

Resolution

± 0.01Hz

Operation conditions

Power supply

3×220/380V±10% 50/60Hz±2Hz

Temperature

-10°C -- +40°C

Humidity

35% -- 85%RH